Goniochromatic assessment of gray scales
for color change
Posted on 2020-07-20 - 16:40
The dependence of color differences on the illumination and viewing directions for
two widely-used gray scales for color change (SDCE and AATCC) was evaluated through
measuring the spectral bidirectional reflectance distribution function (BRDF) by a goniospectrophotometer of metrological quality. Large incidence and viewing angles must be
specially avoided using these gray scales because in these conditions color differences vary
considerably from those established in ISO 105-A02 and ASTM D2616-12. While the visual
appearance of the SDCE and AATCC gray scales for color change is similar, our results
indicate that their goniochromatic properties are different. Finally, some recommendations
regarding observation distance and illumination angle to correctly use these gray scales for
visual experiments are given.
CITE THIS COLLECTION
DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
Ferrero, Alejandro; Bernad, Berta; Campos-Acosta, Joaquin; RICHARD, Noël; Fernandez-Maloigne, Christine; Melgosa, Manuel (2020). Goniochromatic assessment of gray scales
for color change. Optica Publishing Group. Collection. https://doi.org/10.6084/m9.figshare.c.4935222.v1
or
Select your citation style and then place your mouse over the citation text to select it.
Resource Link
SHARE
Usage metrics
Read the peer-reviewed publication
AUTHORS (6)
AF
Alejandro Ferrero
BB
Berta Bernad
JC
Joaquin Campos-Acosta
NR
Noël RICHARD
CF
Christine Fernandez-Maloigne
MM
Manuel Melgosa